enthalpy sample 1

Measured by
Fraunhofer ISE
Measured with TA Q200
Measured according to standard
Comment on measurement
subtraction of blank crucible was not necessary (signal of blank measurement negligible)
Reference
Heating rate
0.25 K/min
Cooling rate
0.25 K/min
Sample mass
10.18 mg
 
Endothermic heat flow Exothermic heat flow
Value Uncertainty Value Uncertainty
Enthalpy
182.8 kJ/kg
0.2 kJ/kg
183.6 kJ/kg
0.1 kJ/kg
Integration lower limit
33 °C
46 °C
Integration upper limit
33 °C
43 °C
Onset temperature
43.69 °C
0.01 K
45.13 °C
0.01 K
Endset temperature
42.27 °C
0.03 K
41.65 °C
0.03 K
Lauric acid: Heating/cooling enthalpy 1
Lauric acid: Heating/cooling enthalpy 2
Reference measurement

Lauric acid: Heating/cooling enthalpy 1

Lauric acid: Heating/cooling enthalpy 2